{"product_id":"new-tecnoscopio-3c80-3-channel-usb-automotive-oscilloscope","title":"New Tecnoscópio 3C80 3-Channel USB Automotive Oscilloscope","description":"\u003cp\u003eCapture the signals behind engine performance with the \u003cstrong\u003eNew Tecnoscópio 3C80 3-Channel USB Automotive Oscilloscope\u003c\/strong\u003e. Designed for sensor and actuator testing in light-duty and diesel vehicles, this diagnostic kit combines signal capture, configurable rotation-signal generation and guided reference functions.\u003c\/p\u003e\u003ch3\u003eKey Benefits\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCompare automotive signals using three input channels.\u003c\/li\u003e\n\u003cli\u003eInvestigate injectors, primary ignition and secondary ignition using the appropriate probes and protection.\u003c\/li\u003e\n\u003cli\u003eConfigure inductive, Hall and inverted Hall rotation signals.\u003c\/li\u003e\n\u003cli\u003eGenerate a signal on channel C while reading on channel A, as described in the source.\u003c\/li\u003e\n\u003cli\u003ePerform relative-compression tests for engines with 3 to 12 cylinders, including the battery-voltage-drop method during cranking.\u003c\/li\u003e\n\u003cli\u003eUse guided reference signals, access shared cloud waveforms and save signal files on your computer, subject to software and service availability.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eModel: New Tecnoscópio 3C80 \/ 3C.\u003c\/li\u003e\n\u003cli\u003eInput channels: 3.\u003c\/li\u003e\n\u003cli\u003eConnection: USB 2.0 Full Speed; powered through USB.\u003c\/li\u003e\n\u003cli\u003eStated input voltage range: −40V to +40V; follow manufacturer probe and attenuation requirements.\u003c\/li\u003e\n\u003cli\u003eStated voltage measurement accuracy: 0.5% typical, up to 1% of full scale; True RMS listed.\u003c\/li\u003e\n\u003cli\u003eOutput channels: 2.\u003c\/li\u003e\n\u003cli\u003eVariable output voltage: −12V to +12V.\u003c\/li\u003e\n\u003cli\u003eOutput impedance: Source lists 50 without a unit; confirm in the manufacturer's specifications.\u003c\/li\u003e\n\u003cli\u003eSource-listed real-time sampling figure: 20MHz, variable with timebase.\u003c\/li\u003e\n\u003cli\u003eSource-listed equivalent sampling figure: 80MHz at the shortest timebase. This does not establish an 80MHz analog bandwidth.\u003c\/li\u003e\n\u003cli\u003eInput impedance: Source entry is expressed as percentages without a usable impedance value; consult the manufacturer.\u003c\/li\u003e\n\u003cli\u003eProduct dimensions and materials: Not supplied.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eMinimum Computer Requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIntel Core i3 processor or AMD equivalent.\u003c\/li\u003e\n\u003cli\u003e4GB RAM.\u003c\/li\u003e\n\u003cli\u003e400MB free storage.\u003c\/li\u003e\n\u003cli\u003eOne USB 2.0 port.\u003c\/li\u003e\n\u003cli\u003eWindows 7 or later, according to the supplied listing. Confirm current software and driver compatibility before purchase.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded in the Kit\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1 USB oscilloscope interface.\u003c\/li\u003e\n\u003cli\u003e1 USB cable.\u003c\/li\u003e\n\u003cli\u003e2 small banana-type alligator clips.\u003c\/li\u003e\n\u003cli\u003e4 small probe needles.\u003c\/li\u003e\n\u003cli\u003e1 capacitive cable clamp.\u003c\/li\u003e\n\u003cli\u003e1 capacitive probe for COP secondary ignition.\u003c\/li\u003e\n\u003cli\u003e1 BNC-to-banana lead with reference.\u003c\/li\u003e\n\u003cli\u003e2 BNC-to-banana leads without reference.\u003c\/li\u003e\n\u003cli\u003e1 voltage attenuator.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThis listing does not specify Wi-Fi connectivity, a transport bag, a protective case or a battery adapter as included. Do not assume the contents of another New Tecnoscópio kit apply to this model.\u003c\/p\u003e\u003ch3\u003eCare \u0026amp; Safe Use\u003c\/h3\u003e\u003cp\u003eFor trained automotive diagnostic users. Follow the manufacturer's manual for grounding, connection points, voltage limits, attenuation and vehicle-system compatibility. Never connect directly to high-voltage ignition circuits without the specified protective accessories. Keep the module and connectors dry, disconnect before cleaning and protect leads and probes during storage.\u003c\/p\u003e\u003cp\u003eNo warranty duration, software license terms or cloud-service access period was supplied. Confirm these details before purchase.\u003c\/p\u003e\u003cp\u003eEquip your diagnostic routine with a three-channel kit for capturing signals, comparing references and investigating engine behavior.\u003c\/p\u003e","brand":"New Tecnoscópio","offers":[{"title":"Default Title","offer_id":42871344431186,"sku":"SKU_1793749867467_296","price":1452.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1718\/7061\/files\/D_NQ_NP_2X_848533-MLA119781920661_102026-F.jpg?v=1793749869","url":"https:\/\/www.buybrazil10.com\/zh\/products\/new-tecnoscopio-3c80-3-channel-usb-automotive-oscilloscope","provider":"BuyBrazil","version":"1.0","type":"link"}